Furuno Lcd Sounder Ls6000 Manual Arts

Posted on by admin
Furuno Lcd Sounder Ls6000 Manual Arts 3,9/5 5050 votes

. 6' ECHO SOUNDER LS-6100. All privileges arranged. All rights set aside. Printed in Asia Printed in Japan PUB.Zero. OME-23690 OME-23690 ( ( DAMI DAMI ) ) LS-6100 LS-6100 Your Nearby Agent/Dealer Your Community Realtor/Dealer Initial Copy: FIRST EDITION: FEB. 2002 2002: JUN.

  • Ecoscandagli LCD e Radar Furuno / FishFinder and Radar Furuno Ecoscandagli LCD Furuno 5' LCD LS ' LCD. Modello 5'LCD SOUNDER 6' LCD. Manual 1/8 TFT LCD-5.
  • View and Download Furuno LS-6100 operator's manual online. 6' ECHO SOUNDER. Marine Equipment Furuno LS-6000 Operator's Manual. Lcd video sounder.
  • Furuno Ls6000 User Guide Furuno ls 6000 operator's manual pdf download, view and download furuno ls 6000 operator's manual online lcd video sounder ls 6000 marine equipment pdf manual.

TABLE OF CONTENTS FOREWORD.iii Program OVERVIEW.iv 1. OPERATION.1 1.1 Control Explanation.1 1.2 Switching the Strength On/Away from.1 1.3 Changing Display Contrast, Elegance.2 1.4 Choosing a Screen, Regularity.2 1.5 Menu Operating Method.5 1.6 Auto Operation.5 1.7 Manual Operation.6 1.8 Choosing Picture Advance Velocity.7. Immediately switch off the strength at the switchbóard if the devices is emitting smoke or fire.

Continued make use of of the apparatus can cause fire or electrical shock. Contact a FURUNO broker for support. Do not really move around the charter boat centered on the level indication on your own. The installer of the gear is solely responsible for the proper set up of the equipment. FURUNO will assume no responsibility for any harm associated with improper installation. Use the specified power wire. Say thanks to you for thinking of and purchasing FURUNO gear.

Find great deals on eBay for furuno 667 sounder. Furuno LCD Sounder LS-6000. FURUNO FMV-601 VIDEO SOUNDER, WITH MANUAL, UNTESTED.

Features The FURUNO LS-6100 is usually a double frequency (50 kHz, 200 kHz) monochrome LCD echo sounder. Comprised of a display unit and a transducér, the LS-6100 shows underwater circumstances on a shiny 6-in . monochrome LCD. Program OVERVIEW Program configuration Products lists Standard supply Name Display Unit LS-6100 520-5PSD Transducer 520-5MSD 520-5PWD 525ST-MSD Triducer (transducer plus spd/temp sensor) 525ST-PWD Tapping mess (4 pcs., 5 a 20 SUS304, 000-802-081) Installation Materials Washing machine head screw B (4 pcs., Meters4 times 20 SUS304, 000-804-742) (CP02-07000) Cable assy. OPERATION 1.1 Control Description How to get rid of the hard cover Spot your thumbs at the middle of the cover up, and then raise the cover while pushing it with your thumbs. Display device 1.2 Turning the Energy On/Off Press the Energy/BRILL key more than one second to switch on the power. 6' Mirror SOUNDER FURUNO Electric powered Company., LTD.

ROM: Fine RAM: Fine Program Zero: 0252308-01. Program version no. Start-up display screen To turn off the power, press and keep down the Strength/BRILL essential until the display goes blank. Solitary frequency screen 50 kHz The sounder uses ultrasonic signals to detect bottom conditions. The lower the frequency of the sign, the wider the detection area. As a result, the 50 kHz frequency is helpful for general recognition and knowing bottom condition.

Free

200 kHz The increased the rate of recurrence of the ultrasonic transmission the much better the resolution. Bottom-zoom display This setting expands bottom level and bottom level seafood in the range width set with Move RANGE on page 3 of the Program menu. This setting is useful for identifying bottom shape. Single rate of recurrence display Base 29.8 Bottom-zoom screen Bottom-zoom screen Bottom-lock screen The bottom-lock screen provides a regular picture on the correct fifty percent of the display screen and a. 1.5 Menus Operating Treatment The LS-6100 provides three selections: Main menus (referred to in text as “menu”), System and Installation. Below is definitely the fundamental menu working procedure. Push the MENU/ESC essential to open the menu.

Web page 1 or Page 2 of the menus appears depending on the page last used. Press the Menus/ESC key to near the menus. The auto mode in make use of is demonstrated as (Autó-Fishing) or (Autó-Cruising) at thé best left corner on the display. Range counteract To display the bottom tail in details in the automated mode, counteract the range as below. Desk 1-1 Default ranges Basic Range Unit metres 10 20 foot 15 30 60 120 200 400 600 1000 fathoms 1. Push the + or - key of the Variety key and the screen should now appear something like thé one below.

Quick Picture and picture advancement speed 1. Push the MENU/ESC key to open the menu. ADVANCE from page 1 of the menus.

Push ► to show the options window. Quit 1/16 Slow Quick Picture advance options window 4. Push the MENU/ESC key to open the menus. Push ▲ or ▼ to select A-SCOPE from page 1 of the menus. Push ► to show the choices window. Press ▲ or ▼ to choose the A-scope display type preferred. 1.13 Erasing Weak Echoes Sediment in the drinking water or reflections fróm plankton may become painted on the screen in reduced intensity sounds.

Appearance of fragile echoes These fragile echoes may become removed as follows: 1. Black widow 2010 download. Push the Menus/ESC key to open the menu.

Use ▲ or ▼ to established the cursor where desired. Picture advancement is stopped until stage 3 can be completed. Push the MARK key once again. The latitude and longitude place at the cursor is output to the navigatór and a vertical line marks location. Make use of ▲ or ▼ to choose GOTO WPT from page 2 of the menus. Press ► to open up the waypoints listing.

- - - - - - - Waypoint checklist 4. Use ▲ or ▼ to choose a waypoint. Press the Menus/ESC essential to close up the menus. 1.19 Alarms Alarm description The LS-6100 has six situations which generate both audio and visible sensors: bottom level alarm, normal fish alarm, bottom locking mechanism fish security alarm, water heat alarm, entrance alarm and rate security alarm.

(The water temperature, entrance and quickness alarms require appropriate detectors.). Security alarm Bottom level FROM: Variety: 10ft Seafood(Regular): On FROM: RANGE: 10ft Seafood(N/L): On FROM: RANGE: 1.0ft FISH Degree: Moderate MENU: Departure ALARM Temp Inside FROM: 72.4 Y RANGE: 1.0 Y Quickness: Off FROM. Alarm range Alarm range marker Bottom part alarm, Seafood alarm (regular): Correct Fish alarm (underside/lock): Still left. Alarm icon: Bottom security alarm: Seafood alarm (normal): Fish alarm (B/L): Temp alarm ( D or Y shown): Rate alarm: Introduction security alarm How the alarm works Note: To turn off an alarm, choose Away from.

1.23 Environment Up Nav Data Shows The user may plan the nav data displays as preferred. Use the Setting key to choose the nav data display you need to set up. Press the Cursor Cushion to display the NAV DATA SETUP window. GRAPHIC DISPLAYS 0.25 XTE GRAPHIC Quickness 17.2 SPEED Image Wind flow APP. 10.3 Velocity WIND GRAPHIC Wpt 03 Location Rng 0.19nm Brg 321 XTE 0.00nmeters Cse 333 waypoint information: Name, Range, Location WAYPOINT GRAPHIC Keeping to destination waypoint COMPASS Image Depth 32.8 DEPTH XTE size. SYSTEM INSTALLATION Choices The System menu mainly is made up of items which once set do not require frequent modification.

You may screen this menus by selecting SYSTEM Menus at page 2 of the menus and pushing ►. Program MENU Web page 1 Vocabulary British. TLL (Target Latitude, Longitude) placement when the Tag key is certainly operated. “TLL” outputs latitude and longitude position. “FURUNO-TLL,” accessible with connection of navigator that can result FURUNO TLL, outputs latitude and longitude, water temperature, depth, etc.

Showing: Boat's program and keeping to a waypoint may be displayed in real or permanent magnetic bearing. Page 3 Fundamental Variety 1 - Simple Variety 8: Set range of each óf the eight simple ranges. Be aware 1: All default basic ranges are usually restored whenever the depth unit is certainly changed. Thus, modify the depth device before altering the simple ranges. Note 2: A variety may not really be lower than the range previous it. Check: Performs diagnostic lab tests. For more details, find paragraph 3.7.

LCD Design: Testing the LCD. For additional details, find paragraph 3.8 Memory space CLEAR: The storage can end up being healed to start afresh with default menus settings. At the set up menu, press ▼ to choose MEMORY CLEAR. Servicing, TROUBLESHOOTING WARNING ELECTRICAL Surprise HAZARD Perform not open the apparatus. Only experienced personnel should function inside the equipment. 3.1 Upkeep Regular servicing is essential for good performance.

Looking at the items listed in the desk below monthly will help maintain your tools in great shape for years to come. 3.6 Troubleshooting The table below provides basic troubleshooting processes which the user may adhere to to recover normal operation.

Troubleshooting desk If Then check out neither echo nor electric battery voltage. Fixed range range fuse. Appears strength supply. No mirror appears if screen progress but the set speed is certainly fixed to “Stop.”. The Range of motion, Memory and NMEA port are checked, with the outcomes proven as OK or NG (No Good).

For any NG, request support. (A specific connector can be needed to test the NMEA slot. Nothing appears if no connection is connected.) 5. INSTALLATION 4.1 Screen Unit Installing considerations The display unit can end up being installed on a desktop, on the overhead or get rid of installed in a cell.

When choosing a mounting location maintain the following in thoughts: Maintain the screen unit out of immediate sunshine. A practical choice would become somewhere between 1/3 and 1/2 of the fishing boat's size from the stern. For planing hulls, a useful location is generally rather far astern, therefore that the transducer is certainly continually in drinking water irrespective of the planing attitude. 520-5PSD 520-5MSD Thru-hull support transducer mounting.

Pit for filling tube Top Half Decrease Half Saw along incline of hull. Building of fairing mass 3.

Drill a ditch simply large sufficiently to pass the threaded filling pipe of the transducér through the huIl, producing certain it will be drilled vertically. 5 times 20 No.1 ° Recording Transom support transducer, mounting flush with hull Installing the transom build transducer on á deep-V huIl This method is used on déep-V hulls ánd provides good functionality because the results of air bubbles are usually minimum. Install the transducér parallel with watér surface area. 4.4 Inside-hull Transducer The thru-hull bracket transducer (520-5PSD, 520-5MSD) may furthermore be installed inside the hull, following the procedure below.

Furuno Echo Sounder

Essential tools You will require the following tools: Sandpaper (#100) Silicon sealant Silicone grease Comments on installation Change off the motor and anchor the motorboat while installing the devices. If the bottom part is shown in darkish grey and the level indication shows up, the installing location is suitable. Go to “Final preparation.” 11. If the bottom part is not displayed in darkish gray tone, the installing place may become unsuitable. Do the following: a) Push the Strength/BRILL essential to switch off the power. Height without acceleration sensor 191mmichael (7-1/2') Elevation with velocity sensor 213mmeters (8-1/2') Height needed at mounting location Note 1: Perform not install the sensor in an area of turbulence or bubbles: near water consumption or discharge open positions; behind strakes, struts, fittings, or hull irregularities; behind eroding color (an sign of turbulence). If you perform not know the transom position, temporarily attach the bracket and sensor tó the transom tó figure out if the plastic shim is definitely needed.

Making use of the two #10 a 1-1/4” self-tapping screws, temporarily screw the group to the hull. Perform NOT tighten up the anchoring screws totally at this period. Affixing the sensor to the bracket 1. If the keeping cover up near the best of the bracket is shut, open it by depressing the latch and revolving the cover up downward. Phase 1 Stage 2 Latch Pivot left arm (2) Keeping cover Stage 3 Action 4 Attaching the sensor to the bracket. 4.6 Optional Water Temp/Speed Sensor Drinking water temp/speed sénsor ST-02MSB and ST-02PSB, which are made for thru-hull installation, are usually optionally available.

Install them as demonstrated below. Increasing considerations Choose a appropriate mounting location thinking of the right after: Select a place free from vibration. Choose a mid-boat flat place. IEC-61162-1/NMEA0183 RD-B +Vout Strength output potential.

100 mA. = The LS-6100 can nourish 12 V strength to GP-310B, GP-320B. The strength voltage must end up being at least 12 Sixth is v to supply power to those devices. NMEA slot setup The NMEA slot can function as an insight interface or input/output interface.

Wind sensor DISPLAY UNIT ¬ Blowing wind Sensor 12 VDC NMEA slot environment: IN/OUT Connection of breeze sensor Nourishing information to RD-30 via the LS-6100 GP-310B Screen UNIT. ® RD-30 12/24 VDC Wind Sensor 12 VDC NMEA slot setting: IN/Out there NMEA mix environment: ON.: Navigator-related data not shown. Specs OF THE Mirror SOUNDER LS-6100 1. Easy recovery essentials for windows 7 64 bit free download.

Common 1.1 TX Frequency 50 kHz or 200 kHz, 50/200 kHz double transmitting selectable 1.2 Transmit Technique Single or dual transmitting 1.3 Output Power 300 Wrms 1.4 TX Rate Maximum. 550 heartbeat/min 1.5 Pulse-length 0.1 to 1.0 master of science.

. Fish Finder 6' LCD SOUNDER Model LS-6100 Discontinued Items For Recreational Ships Excellent seafood/seabed discrimination with customizable Nav Information display FURUNO's LS-6100 fish finder can be small, waterproof and greatest of all powerful. It packs 300 W (2,400 p-p) of result power for unrivaled fish finding efficiency. The LS-6100 provides dual rate of recurrence (50 and 200kHz) for a two-way look at of the world below your motorboat. This device is small plenty of to fit practically anywhere. Yet it features a 6 metallic brite LCD screen that offers a incredibly detailed picture of fish and underside structure.

Associated Contents.